作者(zhe):天衡測控 發布(bu)時間:2023-11-24 20:39:19點擊:116


  電子皮帶秤校準

  1、漂移的原因

  定(ding)期校(xiao)(xiao)準(zhun)(zhun):由于皮帶(dai)秤(cheng)的零點間(jian)隔(ge)受到各方面因素(su)影響,使皮帶(dai)秤(cheng)的零點和(he)間(jian)隔(ge)會發生不同程(cheng)度的漂移,故應(ying)(ying)定(ding)期校(xiao)(xiao)驗(yan)(yan),校(xiao)(xiao)驗(yan)(yan)的周期應(ying)(ying)根(gen)據不同的現場要求(qiu)而定(ding),我(wo)廠的零點校(xiao)(xiao)準(zhun)(zhun)和(he)間(jian)隔(ge)校(xiao)(xiao)準(zhun)(zhun)每周一次(ci)。

  零(ling)點漂移的原因:

  ①石塊或(huo)異(yi)物卡在稱重(zhong)橋架內;

  ②稱重橋架上(shang)積(ji)灰積(ji)料:

  ③由于物料的溫度特性,輸(shu)送機環(huan)形皮帶長度有(you)所(suo)變化(hua);

  ④輸送皮帶(dai)粘料(liao);

  ⑤稱重(zhong)傳感器嚴重(zhong)過載;

  ⑥秤架(jia)的嚴(yan)重變形;

  ⑦電(dian)子(zi)測量單元(yuan)或(huo)儀表(biao)故(gu)障;

  ⑧皮帶跑偏。

  間隔漂移的原因:

  ①測速滾(gun)筒的(de)滑動或其直(zhi)徑的(de)變化(hua);

  ②輸送機皮帶張(zhang)力(li)變化(hua);

  ③稱重傳(chuan)感器嚴重過載;

  ④皮帶(dai)速度(du)的(de)變化;

  ⑤秤(cheng)架的嚴重變形;

  ⑥電(dian)子測量單(dan)元或(huo)儀表故障。

  2、校驗

  校驗電子皮帶秤的校驗方法有掛碼校驗、鏈碼校(xiao)(xiao)(xiao)驗(yan)、實(shi)物校(xiao)(xiao)(xiao)驗(yan)多種,我廠輸煤系統電子(zi)皮帶(dai)秤主要(yao)(yao)采用掛碼校(xiao)(xiao)(xiao)驗(yan)。所謂(wei)掛碼校(xiao)(xiao)(xiao)驗(yan)主要(yao)(yao)是(shi)在皮帶(dai)秤的托輥上(shang)懸掛具有(you)標準重量的砝碼、亦或(huo)者是(shi)在稱重橋架上(shang),模(mo)擬物料運行(xing)時的重量數(shu)據。

  掛碼校(xiao)驗的整個過程應包(bao)括零點校(xiao)驗和間(jian)隔校(xiao)驗。

  ①零(ling)點(dian)(dian)(dian)(dian)校(xiao)(xiao)(xiao)(xiao)驗先(xian)讓皮(pi)帶(dai)空(kong)載運行(xing)(xing)30分鐘,再開(kai)始零(ling)點(dian)(dian)(dian)(dian)校(xiao)(xiao)(xiao)(xiao)驗。若零(ling)點(dian)(dian)(dian)(dian)校(xiao)(xiao)(xiao)(xiao)驗誤差在±0. 05%之內,不(bu)需要(yao)對零(ling)點(dian)(dian)(dian)(dian)進(jin)行(xing)(xing)改變(bian)。這(zhe)時繼續進(jin)行(xing)(xing)零(ling)點(dian)(dian)(dian)(dian)校(xiao)(xiao)(xiao)(xiao)準,總共(gong)須進(jin)行(xing)(xing)3次。若誤差超過(guo)±0. 05%,須進(jin)行(xing)(xing)零(ling)點(dian)(dian)(dian)(dian)改變(bian)。再重新(xin)進(jin)行(xing)(xing)零(ling)點(dian)(dian)(dian)(dian)校(xiao)(xiao)(xiao)(xiao)準,總之要(yao)保證在誤差范(fan)圍之內的連續校(xiao)(xiao)(xiao)(xiao)驗次數不(bu)少于(yu)3次。

  ②間(jian)(jian)隔(ge)校(xiao)(xiao)驗(yan)零點校(xiao)(xiao)驗(yan)合格后,接著進(jin)(jin)行(xing)(xing)(xing)(xing)(xing)間(jian)(jian)隔(ge)校(xiao)(xiao)驗(yan)。在皮帶秤運行(xing)(xing)(xing)(xing)(xing)正常且皮帶上(shang)干凈無(wu)煤情況(kuang)下,將標準掛碼(ma)緩慢放下至(zhi)稱(cheng)重橋架上(shang),開(kai)始間(jian)(jian)隔(ge)校(xiao)(xiao)準。若間(jian)(jian)隔(ge)校(xiao)(xiao)驗(yan)誤(wu)差在±0.5%之內,不需要對間(jian)(jian)隔(ge)進(jin)(jin)行(xing)(xing)(xing)(xing)(xing)改變。繼(ji)續進(jin)(jin)行(xing)(xing)(xing)(xing)(xing)間(jian)(jian)隔(ge)校(xiao)(xiao)準,總共須進(jin)(jin)行(xing)(xing)(xing)(xing)(xing)2次(ci)。若誤(wu)差超過±0.5%,則須進(jin)(jin)行(xing)(xing)(xing)(xing)(xing)間(jian)(jian)隔(ge)改變。重新進(jin)(jin)行(xing)(xing)(xing)(xing)(xing)間(jian)(jian)隔(ge)校(xiao)(xiao)準。總之要保證在誤(wu)差范圍之內的(de)連續校(xiao)(xiao)驗(yan)次(ci)數(shu)不少于2次(ci)